Abstract

We present a study of the results of the treatment of fractures with external fixation. Twenty four patients were treated with this method. Out of these 17 had suffered fractures of the tibia and 7 fractures of the femur. Fifty eight percent of these fractures were open and 70% of the closed fractures were in multiple levels. Union was completed at an average of 22.5 weeks for the fractures of the tibia and 40.4 for the fractures of the femur. The only complications were a case of delayed union and a case of non-union. There was no infection. We conclude that the treatment of fractures by external fixation is as simple and effective as any other conservative or surgical treatment.

References

Anderson R: An automatic method of treatment of fractures of the tibia and the fibula. Surgery, Gynaecology and Obstetrics 1934,58: 639-646

Hoffmann R: Rotules a os pour la reduction dirigee non saglante des fractures congres Francais de Chirurgie, Paris 1938, 601-610

Hoffmann R: Osteotaxis, osteosynthese externe par fiches et rotules. Acta Chirurgica Scandinavica 1954, 107: 72-76

Vidal J, Andrey J, Connes Η, Buscatret C: Etude biomechanique du fixateur externe d' Hoffmann dans les fractures de jambe. Societe de Montpellier searle du 20 Janvier 1970, p. 43-52

Wagner Η: Surgical lengthening or shortening of the femur or the tibia. Leg length discrepancy / The injured Knee. Hungerford D S. Springer - Verlag Berlin, 1977

Edge Α J, Denham R Α: The Portsmouth method of external fixation of complicated tibial fractures. Injury 1979, 11: 13-18

Sunktian W, Hughes S Ρ F: An external fixation device: Preliminary communication. Journal of the Royal Society of Medicine 1979, 72: 831-834

Evans Μ, Kenwright J, Tonner Κ Ε: Analγsis of single-side external fracture fixation. Engineering in Medicine 8, 1979,3:138-142

Bobotas Ν, Reissis Ν, Trouli Η: Resistance of external fixation against stress. Acta Orthopaedica Hellenica 1988, vol 3, Ν 2: 117-121

De Bastiani G, Aldeogheri R, Brivio R L: The treatment of fractures with dynamic axial fixation. Journal of Bone & Joint Surgery 1984, 4: 538-543

Haines F J, Williams Α Ε, Hargadon J Ε, Davies Α R D: Is conservative treatment of displaced tibial shaft fractures justified? Journal of Bone & Joint Surgery 1984, 1: 84-88

Velazco Α, Whitesides Τ Ε, Fleming L L: Open Fractures of the tibia treated with Lottes nail. Journal of Bone & Joint Surgery 1984, 7: 879-885

Tietjens R Β: External fication of the tibial fractures. Journal of Bone & Joint Surgery 1984, 4: 614-615